Title
Sheet
Draw. No.
FANUC LINEAR MOTOR series
DESCRIPTIONS (Detector)
13/16
FANUC LTD
B-65222EN/03-003
DescriptionDesig.DateEdit.
01 02.05.13 KIKUCHI
10. PARAMETER SETTING
Series and editions of applicable servo software :
90B0 / 09 and subsequent editions
#7 #6 #5 #4 #3 #2 #1 #0
2274(FS16
i
)HP2048
2687 (FS15
i
)
HP2048(#0) Linear Motor Position Detection Circuit H :
0:Unavailable (512 times)
1:Available (2,048 times)
(Note)
l When you set this parameter, setting values of the following fundamental
parameters are same as those explained in parameter manual.
FFG, AMR conversion coefficient, Number of position pulses,
Numver of velocity pulses
l This parameter is available only when you use linear motor or separate
detector(linear scale).
l Changing this parameter occurs P/S alarm 000 (PLEASE TURN OFF POWER).
l When you set this parameter, detection unit at FFG=1/1 is (Signal pitch
/512[um]). If you need minimum detection unit (Signal pitch /2048[um]), please
set FFG=4/1.
l When you use nano-interporation, all position feedback pulses from separate
sclase is used as decimal position feedback.
(Example of parameter setting)
After setting HP2048=1, please set fundamental parameters as follows. Please
refer to PARAMETER MANUAL(B-65150, B-65270) for details.
Signal
pitch
PLC0
Number of
velocity pulses
Number of position
pulses /
Conversion coefficient
AMR conversion
coefficient
1 / 2
FFG
No2000#0 No2023 No2024 / No2185 No2112 / No2138 No2084 / No2085
20 0 5000 16000 / 0
1536 / 0
(Medium,Large)
768 / 0
(Small)
5 / 128
(1um Detecton)
50 / 128
(0.1um Detection)
40 0 2500 8000 / 0
768 / 0
384 / 0
5 / 64
50 / 64
2 1 5000 1600 / 10
15360 / 0
7680 / 0
1 / 256
10 / 256
4 1 2500 8000 / 0
7680 / 0
3840 / 0
1 / 128
10 / 128