B-65222EN/03 CONFIGURATIONS AND SELECTION 2.SELECTION METHODS
- 77 -
2.3.2 Calculating the Amount of Regenerative Energy
NOTE
When you use an amplifier using the power supply
regeneration method, you need not calculate the
amount.
The following expressions give the amount of energy regenerated in a
linear motor. If the amount of regenerative energy exceeds the
permissible amount of regenerative energy for the drive amplifier, it is
necessary to provide a separate regenerative discharge unit.
P=(M
T
×V
M
2
-F
F
×V
M
×t
a
)÷(2×F).................................... <1>
Q=(9.8×M
T
-F
F
)-V
M
×(D÷100) ..................................... <2>
P: Deceleration energy (W)
Q: Energy generated at a drop by gravity (W)
F
F
: Friction (N)
t
a
: Rapid traverse acceleration/deceleration time (sec)
F: Rapid traverse count (sec/count)
D: Duty ratio (%) at rapid traverse downward movement
* D < 50
Obtain the amount of regenerative energy for the horizontal axis using
expression <1>. Obtain the amount of regenerative energy for the
vertical axis using expression <1> + expression <2>.
- Amount of regenerative energy for the horizontal axis ≥ P
- Amount of regenerative energy for the vertical axis ≥ P + Q
NOTE
For the permissible amount of regenerative energy
for drive amplifiers and the specifications of
separate regenerative discharge units, refer to the
latest version of "FANUC Servo Amplifier α series
Descriptions" (B-65162E) or that of "FANUC Servo
Amplifier Unit α series Descriptions" (B-65192EN).