B-65222EN/03 START-UP 4.PARAMETER SETTING
- 169 -
Model
Cooling
method
Rated
(N)
POVC1 POVC2 POVCLMT RTCURR
No cooling 1200 32740 345 1024 744
Air-cooled 1440 32728 497 1474 893
6000B/4
*
Water-cooled 2400 32658 1380 4095 1489
No cooling 1800 32708 744 2207 1093
Air-cooled 2160 32682 1071 3177 1311
9000B/2
*
Water-cooled 3600 32730 2968 8826 2186
No cooling 1800 32698 873 2590 1184
Air-cooled 2160 32667 1257 3729 1421
9000B/4
*
Water-cooled 3600 32490 3481 10358 2368
No cooling 3000 32730 471 1396 869
Air-cooled 3600 32714 678 2010 1043
15000C/2
*
Water-cooled 7000 32563 2557 7601 2029
No cooling 3000 32682 1078 3197 1316
Air-cooled 3600 32644 1551 4604 157915000C/3
Water-cooled 7000 32301 5883 17406 3070
When a motor marked with * is used with an αi series amplifier, the
parameters above are not applicable.