2.SPECIFICATIONS SPECIFICATIONS B-65222EN/03
- 8 -
2.2 SPECIFICATION LIST
*1
Model
Item Symbol Unit
300D/4 600D/4 900D/4
Cooling method(*2) - -
No
cooling
Air
cooling
Water
cooling
No
cooling
Air
cooling
Water
cooling
No
cooling
Air
cooling
Water
cooling
Maximum speed - m/s 4 4 4
Upper speed for the
maximum force
- m/s 2.3 2.3 2.3
Continuous force Fc N 50 60 100 100 120 200 150 180 300
Maximum force Fp N 300 600 900
Continuous output Oc kW 0.2 0.24 0.4 0.4 0.48 0.8 0.6 0.72 1.2
Maximum output Op kW 0.7 1.4 2.1
Continuous current Ic Arms 1.4 1.7 2.8 2.8 3.4 5.6 4.2 5.1 8.5
Maximum current Ip Arms 8.5 17.0 25.4
Maximum amplifier current - Ap 20 40 40
Force constant Kf N/Arms 35.4 35.4 35.4
Back electromotive force
constant
Ke Vrms/(m/s) 11.5 11.5 11.5
Armature resistance Ra Ω 3.0 1.5 1.0
Thermal time constant Tt min. 30 15 0.5 30 15 0.5 30 15 0.5
IC CODE(*4) - - 0A8 9A7A7
9W7A
7
0A8 9A7A7 9W7A7 0A8 9A7A7 9W7A7
Coolant(*5) - - - Air Water - Air Water - Air Water
Flow rate - L/min - - 4 - - 4 - - 4
Recommended
pressure
- Mpa - - 0.1 - - 0.1 - - 0.1
Maximum
pressure
- Mpa - - 0.3 - - 0.3 - - 0.3
Cooling
conditions
(*3)
Required
cooling capacity
- W - - 100 - - 200 - - 300
Magnetic attraction (*6) Fa N 750 1500 2250
Weight of the coil slider (*7) W kg 0.8 1.5 2.2
Type of applicable magnet
plate (*8)
-- D D D
*1 Standard values at an ambient temperature of 25(C and a power supply voltage of 200 V
The values may vary depending on the ambient temperature, digital servo software, parameters, power supply voltage, amplifier specifications, and others.
*2 To use "air cooling" or "water cooling," a forced cooling system with a cooling plate (option) is required. For details, see Subsection 2.4.3, "Cooling Plate."
*3 When "no cooling" or "air cooling" is used, the thermal loss differs depending on the materials of parts around the coil slider and machine configuration.
According to the thermal loss, the rating may vary.
*4 Conforms to EN60034-6. IC code "0A8" for "no cooling" is cooling for a movable coil slider. For cooling for a movable magnet plate, the IC code is "0A0".
*5 Primary coolant for forced cooling (coolant for directly cooling the coil slider)
"Air" means ordinary industrial compressed air. "Water" means ion exchanged water (including 5% rust inhibitor).
*6 Approximate magnetic attraction between the coil slider and magnet plate when there is a 0.5-mm mechanical gap between the coil slider and magnet
plate
The value varies depending on the size of the gap.
*7 When "air cooling" or "water cooling" is used, the weight of the cooling plate is added. For details, see the subsection "Cooling Plate" below. When an
incremental linear encoder is used, the weight of the magnetic pole sensor is added. For details, see the subsection "Magnetic Pole Sensor" below.
*8 The type of applicable magnet plate differs depending on the motor model. For details, see the subsection "Magnet Plate" below.