2.SELECTION METHODS CONFIGURATIONS AND SELECTION B-65222EN/03
- 74 -
2.3 POWER SUPPLY MODULE (PSM) SELECTION
2.3.1 Selecting a Power supply Module
Select a power supply module (called a PSM below) required for
driving the linear motor as follows.
NOTE
PSM selection described in this subsection assumes
the use of linear motors only along one axis. When
there is another feed axis or a spindle, consider and
add the PSM capacity required for it.
<1> Check the rated continuous output of the linear motor.
Check the rated continuous output of the linear motor to be used
according to the cooling condition and maximum speed to be
used. Read the rated continuous output value from the
corresponding output versus speed diagram (diagram shown on
the right) in Section 2.3, "FORCE VERSUS SPEED
DIAGRAMS AND OUTPUT VERSUS SPEED DIAGRAMS,"
in Part I, "SPECIFICATIONS."
Example:
- Motor model: Two 300D/4s arranged face to face
- Cooling condition: Water cooling
- Maximum speed to be used: 2 m/s
It can be seen from the output versus speed diagram on the right
of the 300D/4 on page 12 in this manual that the output with
water cooling at a speed of 2 m/s is 0.2 kW. Therefore, the
output of two 300D/4s is:
0.2kW×2=0.4kW
<2> Calculate the maximum output during acceleration/deceleration.
Calculate the maximum output required during acceleration/
deceleration of the linear motor. Use the corresponding
expression in the following table according to the speed range to
be used for the motor model. When multiple motors are to be
driven simultaneously, add the values obtained for the motors.