B-65222EN/03 START-UP 4.PARAMETER SETTING
- 175 -
<2>-b When using A06B-6057-H630 (one-piece analog/digital type),
set up the 7-segment LED digits on the check board as shown
below:
* Letter X stands for an axis
number specified in parameter
No. 1023.
5X
1X
CH1
Phase
CH2
Torque
<3> To measure the activating phase angle, set the following
parameter.
1726 - Parameter for internal data measurement
2115 -
Series 9096: 1328 (for both odd- and even-numbered axes)
Series 90B0: 704 for odd-numbered axis and 2752 for even-
numbered axis
Steps <2> and <3> enable CH0 and CH1 of the SD software to be
used to measure the motor activating phase angle (CH0) and torque
command (CH1).
<4> Start the "SD" software, and make the following setting.
DOS prompt > SD INIT [Enter]
o (Origin of position)
F9 (System setting)
0 (CH0)
2 [Enter] (TCMD)
1.0 [Enter] (1.0A)
1 (CH1)
2 [Enter] (TCMD)
40 [Enter] (Maximum current for servo amplifier to be used)
F10 (Return to main menu.)
(Ctrl)T (XTYT mode selected)
F2 (Data number)
9000 [Enter] (Number of data items to be measured)
* This description uses the 3000B as an example. It differs from
other models only in the current rating of the servo amplifier.
<5> When determining the correction parameters, set the velocity
gain to a rather low value.
<6> For medium-size and large motors, make a reciprocating motion
for 200 mm or more at F1200 (mm/min).
For small linear motors, make a reciprocating motion for 100
mm or more at F1200 (mm/min).