B-66244EN/03 2.FANUC PICTURE (Windows)
- 117 -
Group No:
A group number can be specified when the actuator button or
alternate button is selected. A button with the same group number
operates as a selector switch. In selector switch operation, only
one switch operates in one group; if another switch is turned on,
the switch previously turned on is turned off. A group number
from 1 to 9 can be specified on the same screen.
Number 0 specifies switches that operate alone.
Shortcut key:
If you want to execute an operation set up on the Action tab by
pressing an associated shortcut key, turn on this check box.
An operation associated to the shortcut key setting can be
executed by pressing the key on the display unit, no matter
whether it has a touch panel, or touching the corresponding button
on the touch panel (if available).
The following key types can be selected:
1. Soft keys (FL, F1 - F9, and FR for 10 + 2 soft keys
FL, F1 - F5, and FR for 7 soft keys)
2. Cursor / Page key (←,→↑,↓,Page-UP,Page-DOWN)
3. Edit key (CAN,INPUT,ALTER,INSERT,DELETE)
4. HELP key
Interlock 1:
This function can be specified when the actuator button or
alternate button is selected.
When the interlock signal is on, push-button operation is
interlocked.
Interlock 2:
This function can be specified when the actuator button is
selected.
When the interlock signal is off, push-button operation is
interlocked. When this function is used together with InterLock1,
push-button operation is enabled when both interlocks are
released.
Interlock PMC Area 1, Interlock PMC Area 2:
Specify a type of PMC address for an interlock signal. The
following areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)
Interlock PMC Address 1, Interlock PMC Address 2:
Specify an interlock signal address.
Interlock PMC Bit 1, Interlock PMC Bit 2:
Specify the bit position of an interlock signal by using a number
from 0 to 7.
Blink:
This check box can be specified when the momentary button (with
a lamp), actuator button, or alternate button is selected. Check this
check box to use the blink function.
Blink PMC (Blink PMC Area, Blink PMC Address, Blink PMC Bit):
Specify a signal for blinking the lamp section.
Specify these items in the same way as for Interlock PMC Area,
Interlock PMC Address, and Interlock PMC Bit.