B-66244EN/03 2.FANUC PICTURE (Windows)
- 147 -
Left Align:
A numeral indicated is left-justified.
Non Zero suppress:
In numeral indication, leading zeroes are added.
Set max. and min. Values:
Check this check box to set a valid numeral range for numeral
input.
If a range check finds that an input numeral is outside the valid
range, the background color of the display section for the value
entered through the ten-key pad changes to red.
When the number of decimal places is specified, a range check is
made assuming that a decimal point is placed at the specified
decimal place.
Max. Value:
Set a maximum value to define a valid numeral range. If decimal
places are specified, it is assumed that the same decimal places are
specified in this setting.
Example: When the specified number of decimal places is 3 for
99999, 99.999 is assumed.
Min. Value:
Set a minimum value to define a valid numeral range. Decimal
places are handled in the same way as for Max Value.
Number of digits specification:
Check this check box to specify the number of display digits in the
numeral indication section.
This causes the text box on the right to accept input; set the
number of digits.
The number of digits includes the digits of the decimal point and
the sign, if used.
If the character type or rectangle size is changed, the number of
digits may have to be changed accordingly.
Discriminative number:
To use the data change report function, set the number used to
identify this control, in the range of 1 to 4095. The identification
number must be unique within the project.
If the data change report function is not used, set zero.