5.11.5 Cable Clamping and Shielding
According to the figure below, clamp all cables that require shielding
and are run to the CNC, servo amplifier, spindle amplifier, and so
forth. This clamping method not only secures cables, but also shields
cables. Cable clamping and shielding are a key to stable system
operation. Always perform cable clamping and shielding according to
the method described here.
As shown below, peel off a part of the outer sheath of each cable so
that the shield cover is exposed, then press and retain the exposed part
of the shield against the ground plate with a clamp.
Install a ground plate manufactured by the machine tool builder, as
shown below.
P
‹
Clamp
40mm to 80mm
Ground plate
Cable
Fig. 5.11.5 (a) Cable clamp (1)