Additional Information
Even if replacement is performed reasonably such
as for repairing, this function incorrectly indicates
the * mark when it detects the replacement.
To clear the * mark, follow the steps below to
update the registered data, as described in the
editing section later.
(1) Make the registered data editable. (Parameter
IDW (No. 13112#0) = 1)
(2) On the edit screen, place the cursor on the item
from which you want to delete the * mark.
(3) Operate the soft keys [READ ID], [INPUT], and
[SAVE] in that order.
Editing the servo information screen
1 Assume that parameter IDW (No.13112#0) = 1.
2 Press the MDI switch on the machine operator's panel.
3 Follow the steps shown in "Displaying the servo information
screen" to display the screen as shown below.
4 To move the cursor on the screen, use the
and
keys.