B-63945EN/02 APPENDIX C.BOOT SYSTEM
- 717 -
C.1.1 Displaying the Power ON Sequence
(1)
(2)
(3)
(4)
(5)
(7)
(2)
(6)
Processing is stopped in the event of an
error
SELECT key → SYSTEM MONITOR
Details of display items
(1) WORK RAM test results are displayed. In the event of an error,
however, the sequence is not displayable, and LED indication is
conducted without error display.
(2) BOOT ROM parity test results are displayed. During normal
operation, the series and edition are displayed. In the event of an
error, processing is stopped.
(3) The ID of the DRAM MODULE installed in the CNC is
displayed.
(4) The ID of the SRAM MODULE installed in the CNC is
displayed.
(5) The ID of the FROM MODULE installed in the CNC is
displayed.
(6) The CNC BASIC software in flash memory is checked for
validity and, in the event of an error, an error is displayed. In the
event of an error, clicking the [SELECT] soft key allows you to
select the SYSTEM MONITOR screen.
(7) This message indicates that the CNC BASIC software is being
transferred to flash memory to DRAM.
RAM TEST :END
ROM TEST :END [60W1A]
DRAM ID :xxxxxxxx
SRAM ID :xxxxxxxx
FROM ID :xxxxxxxx
*** MESSAGE ***
LOADING CNC DATA-1 xxxxxx/xxxxxx
END
*** MESSAGE ***
ROM PARITY ERROR:NC BASIC. HIT SELECT.
[SELECT][ YES ][ NO ][ UP ][ DOWN ]
RAM TEST :END
ROM TEST :ERROR