7.INTERFACE BETWEEN CNC AND PMC B-63945EN/02
- 410 -
NOTE
1 For the PMC numbers, see Section 7.2.
2 If there is not “:” key in your keyboard, use “;” or “/”.
3 The signals of the PMC for dual check safety
cannot be traced.
4 Increasing the number of the signal address
changes the capacity of "SAMPLING/ TIME" or
"SAMPLING/ FRAME" in page 1. If the capacity is
changed, the following warning message is
displayed. (The "n" on the message means the
maximum value that is able to input.)
a) In case of "TIME CYCLE" mode
"SAMPLING TIME IS REDUCED TO n SEC."
b) In case of "SIGNAL TRANSITION" mode
"SAMPLING FRAME IS REDUCED TO n."
b) Soft keys
Soft keys on the setting screen of sampling address are as follows
• DELETE: Clears the value of the edit box on the
cursor.
• SYMBOL/ Changes the address display to the symbol
display. However, display of the address
that is not defined the symbol does not
change. This soft key also changes to
"ADDRESS". The following soft keys are
displayed.
• MOVE UP: Exchanges the signal indicated the cursor
for the signal above one line.
• MOVE DOWN: Exchanges the signal indicated the cursor
for the signal below one line.
• DELETE ALL: Clears all of the value of the edit box.
c) Trigger setting
When "SIGNAL TRANSITION" is set on "TRACE MODE" and
"ANY CHANGE" is set on "SAMPLING CONDITION", it can
be set whether to use the setting address as the signals that should
trigger the sampling in the setting signals. As for the signal
address where the trigger was set, "9" is displayed right. Soft
keys on the Trigger setting screen are as follows:
• TRGON: Sets the Trigger on.
• TRGOFF: Sets the Trigger off.
The default setting is trigger on for all signals.
DDRESS: