Error messages that may be displayed on the SIGNAL STATUS screen
Alarm number Faulty location/corrective action Contents
INPUT INVALID Enter a numerical value correctly, as
instructed in "Screen operations using
other keys" in Subsection 7.1.2.
The entered numerical value or its input
format is invalid.
SYMBOL UNDEFINED Enter a defined symbol or bit address. An undefined symbol character string was
entered.
THIS FUNCTION IS
PROTECTED
Cancel the protection by the
programmer protection function or
8-level protection function.
This function is protected by the
programmer protection function or 8-level
protection function.
Error messages that may be displayed on the PMC PARAM screen
Alarm number Faulty location/corrective action Contents
INPUT INVALID Enter a numerical value correctly, as
instructed in Section 7.3.
The entered numerical value or its input
format is invalid.
THIS FUNCTION IS
PROTECTED
Cancel the protection by the
programmer protection function or
8-level protection function.
This function is protected by the
programmer protection function or 8-level
protection function.
Error messages that may be displayed on the SIGNAL TRACE screen
Alarm number Faulty location/corrective action Contents
TRACE FUNCTION IS ALREADY
IN USE
Wait until FANUC LADDER-III or some
other application finishes using the
trace function before executing it.
FANUC LADDER-III or some other
application is currently using the trace
function.
NO SAMPLING ADDRESS Specify a bit address as a sampling
address in the trace parameter.
No sampling address is specified in the
trace parameter.
NO STOP TRIGGER ADDRESS Specify a bit address as the stop
trigger address in the trace parameter.
The stop trigger address is not specified in
the trace parameter.
NO SAMPLING TRIGGER
ADDRESS
Specify a bit address as the sampling
trigger address in the trace parameter.
The sampling trigger address is not
specified in the trace parameter.
Error messages that may be displayed on the trace setting screen
Alarm number Faulty location/corrective action Contents
INPUT INVALID Enter a numerical value that is within
the specified data range of the relevant
trace parameter.
A nonnumeric value or an out-of-range
parameter value was entered.
SYMBOL UNDEFINED Enter a defined symbol or bit address. An undefined symbol character string was
entered.
BIT ADDRESS IS REQUIRED Specify a bit address as the stop or
sampling trigger address.
A byte address was specified as the stop
or sampling trigger address.
INVALID STOP TRIGGER
ADDRESS
Enter a PMC signal address that can
be used as the stop trigger address.
The bit address entered as the stop trigger
address is invalid.
INVALID SAMPLING TRIGGER
ADDRESS
Enter a PMC signal address that can
be used as the sampling trigger
address.
The bit address entered as the sampling
trigger address is invalid.