B-63945EN/02 10.AC SPINDLE
- 555 -
10.1.3 Automatic Setting of Standard Parameters
The standard parameters related to each motor model can be set
automatically.
* The specifications for controlling a motor depend on the
specifications defined by the machine tool builder. The
parameters defined by the machine tool builder are set as the
standard values (initial values) by this automatic setting function.
Therefore, when performing automatic operation, always set
parameters properly according to the parameter list (parameters
4000 and later).
1 Turn on the power in the emergency stop state.
2 Set bit 7 of parameter 4019 to 1.
#7 #6 #5 #4 #3 #2 #1 #0
4019 LDSP
#7 LDSP The parameters for the serial interface spindle are:
0: Not set automatically.
(*)1: Set automatically.
3 Set a motor model code.
4133 Motor model code
Code Motor model Amplifier
301
α0.5/10000i (3000/10000min
-1
)
SPM-2.2i
302
α1/10000i (3000/10000min
-1
)
SPM-2.2i
304
α1.5/10000i (1500/10000min
-1
)
SPM-5.5i
305
α1.5/15000i (3000/150000min
-1
)
SPM-15i
306
α2/10000i (1500/10000min
-1
)
SPM-5.5i
307
α2/15000i (3000/15000min
-1
)
SPM-22i
308
α3/10000i (1500/10000min
-1
)
SPM-5.5i
309
α3/12000i (1500/12000min
-1
)
SPM-11i
310
α6/10000i (1500/10000min
-1
)
SPM-11i
311
α0.5/10000HVi (3000/10000min
-1
)
SPM-5.5HVi
312
α8/8000i (1500/8000min
-1
)
SPM-11i
313
α1/10000HVi (3000/10000min
-1
)
SPM-5.5HVi
314
α12/7000i (1500/7000min
-1
)
SPM-15i
315
α1.5/10000HVi (1500/10000min
-1
)
SPM-5.5HVi
316
α15/7000i (1500/7000min
-1
)
SPM-22i
317
α2/10000HVi (1500/10000min
-1
)
SPM-5.5HVi
318
α18/7000i (1500/7000min
-1
)
SPM-22i
319
α3/10000HVi (1500/10000min
-1
)
SPM-5.5HVi
320
α22/7000i (1500/7000min
-1
)
SPM-26i
321
α6/10000HVi (1500/10000min
-1
)
SPM-11HVi
322
α30/6000i (1150/6000min
-1
)
SPM-45i
323
α40/6000i (1500/6000min
-1
)
SPM-45i
324
α50/4500i (1150/4500min
-1
)
SPM-55i
325
α8/8000HVi (1500/8000min
-1
)
SPM-11HVi
326
α12/7000HVi (1500/7000min
-1
)
SPM-15HVi
327
α15/7000HVi (1500/7000min
-1
)
SPM-30HVi