7.INTERFACE BETWEEN CNC AND PMC B-63945EN/02
- 418 -
7.6 LADDER DIAGRAM MONITOR AND EDITOR SCREENS
([PMC LADDER])
The PMC LADDER menu contains the screens related to PMC
Ladder diagrams, such as the program list screen and the LADDER
DIAGRAM MONITOR/EDITOR screens.
You can switch to the PMC LADDER menu by operating on the
"SYSTEM" key and then the [PMC LADDER] soft key.
PMC main menu
LIST
LADDER
PMC LADDER
<
Program list screen
LADDER DIAGRAM
MONITOR/EDITOR screen
PMC LADDER menu
SYSTEM
Clicking the [LADDER] soft key causes the sequence program to be
dynamically displayed, allowing you to monitor operation. The editor
screen allows you to make changes to relay and functional instructions
in the sequence program to change the operation of the sequence
program.
The ladder diagram display/editor functions consist of the following
screens:
(1) Ladder diagram display screen (LADDER DIAGRAM
MONITOR screen)
Displays ladder diagrams to monitor the current states of relays,
coils, and so on.
(2) COLLECTIVE MONITOR screen
Displays only a selected ladder net to monitor the current states
of relays, coils, and so on.
(3) LADDER DIAGRAM EDITOR screen
Allows you to edit a ladder diagram in units of nets.
(4) NET EDITOR screen
Allows you to edit a single net in a ladder diagram.
(5) PROGRAM LIST VIEWER screen
Allows you to select the subprogram to be displayed on the
LADDER DIAGRAM MONITOR screen.
(6) PROGRAM LIST EDITOR screen
Allows you to edit a ladder program in units of subprograms.
Also allows you to select the subprogram to be edited on the
LADDER DIAGRAM EDITOR screen.