B-63945EN/02 7.INTERFACE BETWEEN CNC AND PMC
- 401 -
7.5.7 Data Input/Output ([I/O] Screen)
To move to the I/O screen, press the [I/O] soft key.
On this screen, sequence programs, PMC parameters and PMC
message data for multi-language display can be written to the
specified device, read from the device, and compared. The query
selection cursor, which moves vertically from one question to another,
is displayed, as is the option selection cursor, which moves
horizontally from one option to another.
The following types of devices can be used for input/output. The
desired device type can be selected by positioning the query selection
cursor to "DEVICE" and moving the option selection cursor to that
type.
• MEMORY CARD: Data can be output to and input from a
memory card.
• FLASH ROM: Data can be output to and input from flash
ROM.
• FLOPPY: Data can be output to and input from handy
files or floppy cassettes.
• OTHERS: Data can be output to and input from other
general-purpose RS-232C input/output
devices.
The multi-path PMC system enables an I/O target PMC to be selected.
In STATUS in the lower part of the screen, a detailed explanation of
execution and the execution status are displayed. During write, read,
and comparison, the size of the data already transferred is indicated as
the execution (intermediate) result.