Example of setting)
Example 1)
When Z phase interval = 50 mm and detection unit = 1 µm
Reference counter = 50,000/1 = 50,000
Example 2)
When detection unit = 0.001° with a rotation axis
Reference counter = 360/0.001 = 360,000
Example 3)
When there is only one Z phase as in the case of a linear scale
Set a simple number such as 10000 and 50000 for the reference counter.
6. Turn off the power then back on.
FD
r
Desi
n
Page
Title
1
1
Data
Desi
n Description
Data
FANUC Series30i /31i /32i -MODEL A
Maintenance manual
Appliance of 9 digits for the reference counter on the
servo setting screen Ver.02
B-63945EN/02-04
05.06.14
K. Tanaka
Draw
No.
05.10.04
02
P4 The error in writing of parameter No.2000
has been corrected.
Y. Fukui