7.INTERFACE BETWEEN CNC AND PMC B-63945EN/02
- 384 -
Table 7.3.2 (b) Addresses of PMCs for the Series 30i/31i/32i-A
30i/31i/32i-A
Function Symbol
First PMC
Second PMC
(option)
Third PMC
(option)
Dual-check
safety PMC
(option)
Message display A
• Display request A0 to A249 A0 to A249 A0 to A249 A0 to A249
• Status display A9000 to A9249 A9000 to A9249 A9000 to A9249 A9000 to A9249
Timer T
• Variable timer T0 to T499 T0 to T79 T0 to T79 T0 to T79
• Variable-timer precision
(Note 2)
T9000 to T9499 T9000 to T9079 T9000 to T9079 T9000 to T9079
Counter C
• Variable counter C0 to C399 C0 to C79 C0 to C79 C0 to C79
• Fixed counter C5000 to C5199 C5000 to C5039 C5000 to C5039 C5000 to C5039
Keep relay K
• User area K0 to K99 K0 to K19 K0 to K19 K0 to K19
• System area K900 to K999 K900 to K999 K900 to K999 K900 to K999
Data table D D0 to D9999 D0 to D2999 D0 to D2999 D0 to D2999
Subprogram P P1 to P5000 P1 to P512 P1 to P512 P1 to P512
Label L L1 to L9999 L1 to L9999 L1 to L9999 L1 to L9999
NOTE
1 This area is reserved for PMC management
software. No I/O can be allocated in this area. Do
not use it in user programs.
2 This area is used to specify the precision of a
variable timer.
Don’t modifiy the value of timer and precision
except for same value when working the timer
-Don’t set the value other than the following range.
If above rules are violated, the working of the timer
is not guaranteed.
The rage other than from T9000 to T9499 are
reserved.
The value of precision
0: Default (8msec or 4msec)
1: 1msec
2: 10msec
3: 100msec
4: 1sec
5: 1min
3 This area is common memory for the multi-PMC
function. It is possible for each program to read
the same value from, and write it to, the area.
4 No extra relay is available for the dual-check safety
PMC.