B-63945EN/02-01
Title
Draw
No.
Ed. Date Design Description
Date Design. Apprv.
4/5
page
FANUC Series 30i/300i/300is-MODEL A
FANUC Series 31i/310i/310is-MODEL A5
FANUC Series 31i/310i/310is-MODEL A
FANUC Series 32i/320i/320is-MODEL A
The correction of MAINTENANCE MANUAL
Page No.676
PW0008 CPU SELF TEST ERROR(DCS PMC) The DCS PMC detected the error in the CPU self test
function and RAM check function.
PW0009 CPU SELF TEST ERROR(PMC) The PMC detected the error in the CPU self test function and
RAM check function.
PW0010
SAFE I/O CROSS CHECK ERROR(DCS
PMC)
The DCS PMC detected the error of system define safe I/O
in the I/O cross check function.
PW0011
SAFE I/O CROSS CHECK ERROR(PMC)
The PMC detected the error of system define safe I/O in the
I/O cross check function.
PW0012
USER I/O CROSS CHECK ERROR(DCS
PMC)
The DCS PMC detected the error of user define safe I/O in
the I/O cross check function.
PW0013
USER I/O CROSS CHECK
ERROR(PMC)
The PMC detected the error of user define safe I/O in the I/O
cross check function.
PW0014
CPU TEST ALARM An error occurred in a CNC CPU test.
PW0015
SAFETY PARAM ERROR The CNC detected error for safety parameter check function.
PW0016
RAM CHECK ERROR The CNC detected error in RAM check function.
PW0017
INEXECUTION OF SAFETY
FUNCTIONS
The CNC detected abnormal condition in the execution of
CNC safety functions.
PW0018
CRC CHECK ERROR The CNC detected the CRC check error in the CNC ROM.
Page No.678
SP1700
SAFETY PARAM ERROR
The CNC CPU detected error in safety parameter check
function.
Page No.679
OH0704 OVERHEAT Spindle overheating reported because a spindle speed
fluctuation was detected.
- Relax the cutting conditions if the cutting load is heavy.
- Check whether the cutting tool is blunt.
- It is likely that the spindle amplifier is faulty.
Page No.680
DS0006 ILLEGAL EXECUTION SEQUENCE The malfunction prevention function detected an illegal
execution sequence.
DS0007 ILLEGAL EXECUTION SEQUENCE The malfunction prevention function detected an illegal
execution sequence.
DS0008 ILLEGAL EXECUTION SEQUENCE The malfunction prevention function detected an illegal
execution sequence.
DS0009 ILLEGAL EXECUTION SEQUENCE The malfunction prevention function detected an illegal
execution sequence.
DS0010 ILLEGAL REFERENCE AREA The malfunction prevention function detected an illegal
reference area.
DS0011 ILLEGAL REFERENCE AREA The malfunction prevention function detected an illegal
reference area.