3. TROUBLESHOOTING
B-65165E/02 TROUBLESHOOTING AND ACTION
- 145 -
(2) If an alarm is issued during motor activation
(a) Influence of noise
Referring to Chapter 5, "Installation," of "FANUC SERVO
AMPLIFIER α series Descriptions (B-65162E)," check the
GND-related wiring. If the signal cable of the spindle sensor
is bundled with the power line of the servo motor, separate
them from each other.
3.4.1.2 Alarm code 01
The inside temperature of the motor is higher than the specified
temperature.
(1) If this alarm is issued during cutting (the motor temperature is
high)
(a) Check the cooling state of the motor.
<1> If the cooling fan of the spindle motor is stopped, check
the power supply of the cooling fan. If the cooling fan
is still inoperative, replace it with a new one.
<2> When a liquid-cooled motor is used, check the cooling
system.
<3> When the ambient temperature of the spindle motor is
higher than the specified temperature, lower the
ambient temperature to satisfy the specification.
(b) If this alarm is issued even when the load meter fluctuates in
a limited range, check the short-period rating. If the
specified value is exceeded, reduce the load.
(2) If this alarm is issued under a light load (the motor temperature is
high)
(a) When the frequency of acceleration/deceleration is too high
Set such a use condition that the average including output at
acceleration/deceleration does not exceed the continuous
rating.
(b) The parameters specific to the motor are not set correctly.
Refer to "FANUC AC SPINDLE MOTOR α series
Parameter Manual (B-65160E)."
(3) If this alarm is issued when the motor temperature is low
(a) The spindle sensor feedback cable is faulty.
Replace the cable.
(b) The SPM control printed circuit board is faulty.
Replace the SPM control printed circuit board or SPM.
(c) The motor (internal thermostat) is faulty.
Replace the motor.