3. TROUBLESHOOTING
B-65165E/02 TROUBLESHOOTING AND ACTION
- 165 -
3.4.2.3 Alarm code 42
<1> The one-rotation signal of the α position coder is not generated.
<2> The one-rotation signal of the MZ sensor or BZ sensor is not
generated.
<3> The one-rotation signal of α position coder S is not generated.
Troubleshooting when this alarm is issued
(a) The setting of a parameter is incorrect.
Referring to "FANUC AC SPINDLE MOTOR α series
Parameter Manual (B-65160E)," check the parameter for
sensor setting.
(b) The MZ sensor or BZ sensor is not adjusted correctly.
Adjust the sensor according to Subsection 4.3.4 of Part I of
this manual. If the sensor cannot be adjusted or the signal is
not observed, replace the connection cable and sensor.
(c) The α position coder is faulty.
Check the check pin PSD on the spindle check board. If the
signal is not generated per rotation, replace the connection
cable and position coder.
(d) The SPM is faulty.
Replace the SPM or SPM control printed circuit board.
3.4.2.4 Alarm code 43
The position coder signal of the spindle on the mater side used in the
differential speed mode is disconnected.
Troubleshoot as in the case of alarm code 27.
3.4.2.5 Alarm code 44
An error occurred in the A/D converter.
When this alarm is issued, replace the SPM or SPM control printed
circuit board.
3.4.2.6 Alarm code 46
The one-rotation signal of the position coder cannot be detected
normally during thread cutting.
Troubleshoot as in the case of alarm code 41.