9.LASER SOFTWARE FUNCTION B-70315EN/02
- 266-
9.4 POWER FEEDBACK FUNCTION BASED ON THE ACTUAL
OUTPUT ESTIMATION METHOD
9.4.1 Overview
Based on specified output conditions, this function estimates an actual
output by using the data table in which the relationships between the
specified output conditions and actual outputs are registered, and
exercises feedback control, aiming at the estimated value. Necessary
data needs to be registered beforehand in the data table.
The feedback gain and compensation clamp value are the same as
used with the conventional feedback control function. (A feedback
gain is set in PRM No. 15208, and a compensation clamp value is set
in PRM No. 15209.)
9.4.2 Data Table
9.4.2.1 Method of registration
(1) Set bit 0 (MNT) of parameter No. 15160 and bit 1 (PTB) of
parameter No. 29000 to 1 to enable display of the data table
screen for actual output estimation.
#7 #6 #5 #4 #3 #2 #1 #0
15160 MNT
MNT
0: Does not display the laser maintenance screen.
1: Displays the laser maintenance screen.
#7 #6 #5 #4 #3 #2 #1 #0
29000 PTB PFB
PFB Pulse power feedback control based on the actual output estimation
method is:
0 : Not used.
1 : Used.
PTB On the data table screen for actual output estimation, data input is:
0: Disabled.
1: Enabled.
When this parameter is set to 0, the screen is not displayed, and data
cannot be input.
Usually, set this parameter to 0 to prevent the data from being
modified inadvertently.