E.PARAMETER LIST APPENDIX B-70315EN/02
- 332 -
E.16 AUTOMATIC AGING FUNCTION
15320 Command power for power compensation coefficient calculation
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
15321 Oscillation frequency command for power compensation coefficient
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
15322 Pulse duty cycle command for power compensation coefficient
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
15323 Command time for power compensation coefficient calculation
[Data type] Word
[Unit of data] sec
[Valid data range] 0 to 32767
15324 Gas pressure setting for normal compensation (50Hz)
[Data type] Word
[Unit of data] (1=13Pa)
[Valid data range] 0 to 32767
15325 Gas pressure setting for normal compensation (60Hz)
[Data type] Word
[Unit of data] (1=13Pa)
[Valid data range] 0 to 32767
15326 Power command when aging is performed with the automatic aging
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
15327 Oscillation frequency command for aging
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000