B-70315EN/02 APPENDIX E.PARAMETER LIST
- 295 -
E.1 PARAMETERS FOR ENABLING/DISABLING VARIOUS
FUNCTIONS
#7 #6 #5 #4 #3 #2 #1 #0
15000 FLT CLB BMO AGA LGC LPC
[Data type] Bit
LPC Power control function
0: Invalid (standard)
1: Valid
LGC Two stage gain selection of intra-tube pressure control
0: Invalid
1: Valid (standard)
(When this bit is 1, PRM No. 15245 becomes valid.)
AGA Assist gas preparation check with beam on
0: Valid (standard)
1: Invalid (for maintenance)
BMO Beam on only with beam off
0: Invalid (standard)
1: Valid (for manual only and maintenance)
CLB Power compensation
0: Disabled
1: Enabled (standard)
FLT Filter in power control
0: Invalid
1: Valid (standard)
#7 #6 #5 #4 #3 #2 #1 #0
15001 LHC PC8 NGC PES G0B EXA
[Data type] Bit
EXA Selection of assist gas
0: 3 types (standard)
1: 7 types
G0B When G00 is specified, a beam
0: Outputs (standard).
1: Does not output.
PES Piercing time during machine lock or dry run
0: Enabled (standard)
1: Disabled
NGC
0: Presets an integral gas pressure control value.
1: Does not preset an integral gas pressure control value.
PC8 The power compensation function
0: Specifies a fixed value for the power.
1: Increases the power in eight levels.