B-70315EN/02 9.LASER SOFTWARE FUNCTION
- 269 -
(2) Press the operation key "Setting" of the CNC. Then, press the
soft keys displayed at the bottom of the CNC screen as shown
below.
POWER SET DATA
STATUS MAINTE.
PWR FB PWS TC
Time constant
measurement screen
PW.OFS ACT.TM ALARM
(3) Start a measurement by pressing the [START] soft key on the
dedicated time constant measurement screen. Perform internal
discharge at the rated output for a certain time, then stop the
beam command. Next, measure the time required until the
monitored value of the power sensor becomes lower than 36.8%
of the rated output. Set the measured time in PRM No. 29005 as
the time constant of the primary delay filter.
29005 Power sensor time constant
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
Set a time constant for the power sensor.