B-70315EN/02 APPENDIX E.PARAMETER LIST
- 303 -
E.2 DISCHARGE TUBE SELECTION
#7 #6 #5 #4 #3 #2 #1 #0
15025 PS8 PS7 PS6 PS5 PS4 PS3 PS2 PS1
#7 #6 #5 #4 #3 #2 #1 #0
15026 PS16 PS15 PS14 PS13 PS12 PS11 PS10 PS9
[Data type] Bit
PS1 to PS16 Power supply selection when half of the discharge tubes are used
Set the bit for each discharge tube to be used to 1, and set the other
bits to 0.
#7 #6 #5 #4 #3 #2 #1 #0
15027 PS8 PS7 PS6 PS5 PS4 PS3 PS2 PS1
#7 #6 #5 #4 #3 #2 #1 #0
15028 PS16 PS15 PS14 PS13 PS12 PS11 PS10 PS9
[Data type] Bit
PS1 to PS16 Power supply selection when all the discharge tubes are used
Set the bit for each discharge tube to be used to 1, and set the other
bits to 0.
NOTE
Parameters No. 15026 and No. 15028 and
provided for future addition of power supply units.
In the current specifications, this parameter is not