7. PARAMETERS
279
01460 Upper limit of feedrate for F1 digit command
(F1 to F4) [mm/min]
M series
01461 Upper limit of feedrate for F1 digit command
(F5 to F9) [mm/min]
01465 Virtual radius for feedrate about rotation axis
[Increment system]
M series
PRM
1408#0
17) For acceleration/deceleration control
01601
Acceleration/deceleration control
#2 OVB : Cutting feed block overlap is not performed (0)/
is performed (1).
#4 RTO : Block overlap in rapid traverse is not
performed (0)/performed (1)
#5 NCI : Imposition check at deceleration is performed
(0)/not performed (1)
#6 ACD : Automatic corner deceleration function is used
(0)/not used (1)
M series
PRM1722
M series
01602 Acceleration/deceleration control
#0 FWB : Linear acceleration/deceleration before
interpolation is type A (0)/type B (1)
#2 COV : The outer arc cutting feedrate change function
of the automatic corner override function is: not
used (0)/used (1)
#3 BS2 : Acceleration/deceleration before interpolation
for cutting feed in the advanced preview
mode/high–precision contour control mode is,
of exponential or linear type as specified by
PRM1602#6 (0)/of bell–shaped type (1)
#4 CSD : Automatic corner deceleration is controlled by
angle (0)/feedrate (1).
#5 G8S : Serial spindle advanced preview control is,
disabled(0)/enabled(1)
#6 LS2 :
0
BS2 LS2 Acceleration/deceleration
0 Exponential acceleration/de-
celeration after interpolation
0
1 Linear acceleration/decelera-
tion after interpolation
1 0 Bell–shaped acceleration/de-
celeration after interpolation
M series
M series
M series