16. DIGITAL SERVO
829
2) Axis setting screen
The axis setting screen displays the information shown below:
AXIS SETTING O1000 N00001
AXIS NAME AMP M1 M2 1–DSF Cs TNDM
1XA1–L 0 00 01
2YA1–M 1 0 1 00
3ZA2–L 0 0 0 10
4AA3–L 0 0 0 02
5BA3–M 0 0 0 00
6CA4–L 0 0 0 00
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINTE ][ ][(OPRT)]
This axis setting screen displays the following items:
D AXIS (controlled axis number)
This item is the placing of the NC controlled axis.
D NAME (controlled axis name)
D AMP (type of the amplifier connected to each axis)
D M1 (connector number for separate detector interface unit 1)
This item is the number of the connector for separate detector interface
unit 1, specified in PRM1931.
D M2 (connector number for separate detector interface unit 2)
This item is the number of the connector for separate detector interface
unit 2, specified in PRM1932.
D 1–DSF
This item is the value specified in bit 0 (parameter 1 DSP) of PRM1904.
It is 1 for an axis (such as a learning control axis, high–speed current
loop axis, or high–speed interface axis) that exclusively uses a DSP,
which is usually shared by two–axes.
D Cs: Cs contour controlled axis
This item is the value specified in PRM1933. It is 1 for the Cs contour
controlled axis.
D TNDM (M series only)
This item is the number specified in PRM1934. Consecutive odd and
even numbers are displayed for the master and slave axes for tandem
control.
3) Amplifier maintenance screen
The amplifier maintenance screen displays maintenance information
for servo amplifiers. This screen consists of the following two pages,
either of which can be selected by pressing the
PAGE
or
PAGE
key.