19. MAINTENANCE FUNCTION
891
0102
Specification number of input/output device
Set value Input/output device
0 RS–232–C (Used control codes DC1 to DC4)
1 FANUC CASSETTE ADAPTOR 1 (FANUC CASSETTE B1/ B2)
2 FANUC CASSETTE ADAPTOR 3 (FANUC CASSETTE F1)
3 FANUC PROGRAM FILE Mate, FANUC FA Card Adaptor
FANUC FLOPPY CASSETTE ADAPTOR, FANUC Handy File
FANUC SYSTEM P-MODEL H
4 RS–232–C (Not used control codes DC1 to DC4)
5 Portable tape reader
6 FANUC PPR
FANUC SYSTEM P-MODEL G, FANUC SYSTEM P-MODEL H
0103
Baud Rate
1: 50 5: 200 9: 2400
2: 100 6: 300 l10: 4800
3: 110 7: 600 11: 9600
4: 150 8: 1200 12: 19200 [BPS]
19.1.2 Output of data
* In the alarm state, data output is disabled in some cases.
19.1.2.1 Outputting CNC parameters
1. Enter EDIT mode or the emergency stop condition.
2. Press
SYSTEM
key and soft key [PARAM] to display parameter screen.
3. Press soft key [(OPRT)] ,and soft key
.
4. Press soft key [PUNCH] and [EXEC],and the parameters are started to
be output.
19.1.2.2 Outputting PMC parameters
1. Select MDI mode.
2. Press
SETTING
OFFSET
key then soft key [SETTING] to select a setting screen.
3. Set the cursor to PARAMETER WRITE and input
1
and
INPUT
. At
this time, alarm 100 will be generated.
4. Press
SYSTEM
key and soft key [PMC].
5. Press soft key [PMCPRM] and soft key [KEEPRL]
6. Set the cursor to K900 (on the SB7) or K17 (on the SA1) and set the first
bit to 1.
X X X X X X 1 X
INPUT
Where, mark x is a former value
Thus, data input/output screen has been selected.
7. Select EDIT mode.