7. PARAMETERS
315
03205 Change function of the extended edit, setting of
screen display
#0 COL : Any colons (:) in the comments of the program
are converted to letter O (0)/displayed or
output as is (1)
#1 CHG : When the change function of the extended edit
function is used, the cursor is moved to the
target position after choosing (0)/before
choosing (1)
#2 CMO: In extended tape editing, the copy or move
operation, is performed in the usual way(0)/can
also copy or move data from a program to a
keyin buffer in units of words(1)
#3 PNS : On the program screen, a search by a cursor
key is, performed(0)/not performed(1)
#4 OSC : On the offset screen, offset value erasure by a
soft key is, enabled(0)/disabled(1)
#7 MCK :
The system tape memory check function is:
not used (0)/used (1)
Must not
be used
03206 Program copy operation between two paths,
setting of history functions
#0 PCP : Program copy operation between two paths is
disable (0)/enable (1)
#1 MIF : Editing of the maintenance information screen
is, not prohibited(0)/prohibited(1).
#4 PHS : The selection of an operation history signal
and PRM12801–12900 are, not
linked(0)/linked(1)
03207 Display of the external operator message
#0 OM4 : A message displayed on the external operator
message screen can have, up to 256
characters, and just a single message can be
displayed(0)/up to 64 characters, and up to
four messages can be displayed(1)
03208 Automatic screen erase
#0 SKY : The function key on the MDI panel is,
enabled(0)/disabled(1)
#1 COK : The automatic screen erase function is,
enabled(0)/disabled(1)
PRM3123
03209 Display of the program number
#0 MPD : When a subprogram is executed, the main
program number is, not displayed (0)/
displayed (1)
03210 Password
O9000 to
O9999
03211 Keyword
PRM
3202#4
03216 Increment in sequence numbers inserted
automatically
PRM
0000#5