7. PARAMETERS
287
01816 Detection multiply ratio (DMR) <Axis>
#4 DM1 :
#5 DM2 :
#6 DM3 :
DM3 DM2 DM1 DMR DM3 DM2 DM1 DMR
0 0 0 1/2
0011
0 1 0 3/2
0112
1 0 0 5/2
1013
1 1 0 7/2
1114
Move amount per one rotation of the motor
Position feedback pulse per one rotation of
the motor DMR
Detection unit =
To be set
with the
flexible
feed gear
parameters
PRM2084
and
PRM2085
01817 Tandem control, linear scale with absolute
address reference mark
<Axis>
#4 SCP : If PRM1802#2 is set to 1, the scale zero point
of the linear scale with absolute addressing
reference marks is, on the negative direction
side(0)/on the positive direction side.(1)
#6 TAN : Tandem control is not applied (0)/applied (1).
01818 Linear scale I/F with absolute address
reference mark
<Axis>
#0 RFS : On an axis using a linear scale with absolute
addressing reference marks, if an automatic
reference position return (G28) is made before
the reference position is established, the
reference position is established first, then a
movement to the reference position is
made(0)/a movement to the reference position
is not made, but the operation is completed(1)
#1 RF2 : On an axis using a linear scale with absolute
addressing reference marks, if an automatic
reference position return (G28) is made after
the reference position is established, a
movement to the reference position is
made(0)/a movement to the reference position
is not made, but the operation is completed(1)
#2 DG0 : On an axis using a linear scale with absolute
addressing reference marks, a reference
position return by jog feed or a rapid traverse
command is, disabled(0)/enabled(1)