16
16.2 FSSB Setting Screen
832
The amplifier setting screen displays the following items:
D NO. (controlled axis number)
For this item, enter a value of between 1 and the maximum number of
controlled axes. If a number that falls outside this range is entered, the
warning message “INVALID FORMAT” appears. If the entered
controlled axis number is duplicate or 0, the warning message
“SPECIFIED DATA IS OUT OF RANGE” appears when soft key [SET]
is pressed to assert the entered value. In this case, no value can be
entered for the parameter.
2) Axis setting screen
AXIS SETTING O1000 N00001
AXIS NAME AMP M1 M2 1–DSF Cs TNDM
1XA1–L 0 00 01
2YA1–M 1 0 1 00
3ZA2–L 0 0 0 10
4AA3–L 0 0 0 02
5BA3–M 0 0 0 00
6CA4–L 0 0 0 00
>_
MDI **** *** *** 13:11:56
[SETTING][ ][ READ ][ ][ INPUT ]
On the axis setting screen, the following items can be specified:
D M1 (connector number for pulse module 1)
For an axis that uses pulse module 1, enter a connector number using
a number in the range of between 1 and the maximum number of axes
for pulse module 1. When pulse module 1 need not be used, enter 0.
If a number that falls outside the valid range is entered, the warning
message “INVALID FORMAT” is displayed.
D M2 (connector number for pulse module 2)
For an axis that uses pulse module 2, enter a connector number using
a number in the range of between 1 and the maximum number of axes
for pulse module 2. When pulse module 2 need not be used, enter 0.
If a number that falls outside the valid range is entered, the warning
message “INVALID FORMAT” is displayed.
D 1–DSF
Enter 1 for the following axes, each of which exclusively uses a DSP,
which is usually shared by two–axes. If a number other than 0 or 1 is
entered, the warning message “INVALID FORMAT” is displayed.
⋅ Learning control axis
⋅ High–speed current loop axis
⋅ High–speed interface axis
D Cs (Cs contour controlled axis)
Enter 1 for the Cs contour controlled axis. If a number other than 0 or
1 is entered, the warning message “INVALID FORMAT” is displayed.
D TNDM
Enter odd and even numbers for the master and slave axes for tandem
control. These numbers must be consecutive and in the range of
between 1 and 8. If a number that falls outside the valid range is entered,
the warning message “INVALID FORMAT” is displayed.