10. PMC
655
(3) System parameter screen (3/3)
On this screen, make settings related to the I/O Link assignment
selection function.
Display information
• ENABLE SELECTION
[NO] : Does not use the I/O Link assignment data selection
function.
[YES] : Uses the I/O Link assignment data selection function.
When [NO] is specified for both of channel 1 and channel 2, the I/O
Link assignment data selection function setting screen described
in item (4) of Subsection 10.1.3.6, “Setting screens” is not
displayed.
• BASIC GROUP COUNT :
This parameter divides the I/O Link assignment data into the
basic group section and the parameter selection group
section. Set the number of groups in the basic group section.
Enter a value from 0 to 16, then press the [INPUT] soft key.
Example
3 : BASIC GROUP COUNT 0 to 2 groups
Parameter selection group section 3 to 15 groups