13
13.2 Diagnosis Information (DGN) List
776
#7
#6 #5 #4 #3 #2 #1 #0
409DGN
SPE S2E S1E SHE
Refer to this diagnosis when ALM750 has generated.
SHE 0: Serial communication module is correct on CNC side.
1: An error occurred in serial communication module on CNC side
S1E 0: 1st spindle started normally in spindle serial control.
1: 1st spindle did not start normally in spindle serial control.
S2E 0: 2nd spindle started normally in spindle serial control.
1: 2nd spindle did not start normally in spindle serial control.
SPE In spindle serial control serial spindle parameters
0: Satisfy start condition of spindle unit
1: Do not satisfy start condition of spindle unit
410
Load meter of 1st spindle [%]
DGN
411
Speedometer of 1st spindle [min
–1
]
DGN
412
Load meter of 2nd spindle [%]
DGN
413
Speedometer of 2nd spindle [min
–1
]
DGN
414
Position error in 1st spindle synchronous control mode [Pulse]
DGN
415
Position error in 2nd spindle synchronous control mode [Pulse]
DGN
416
Absolute value of synchronization error between 1st and 2nd
spindles [Pulse]
DGN
NOTE 1 pulse = 360/4096 (_)
417
Feedback information of 1st spindle position coder
DGN
418
Position error of 1st spindle position loop mode
DGN
419
Feedback information of 2nd spindle position coder
DGN
420
Feedback information of 2nd spindle position coder
DGN
421
Feedback information of the position coder of the third spindle
DGN
422
Position deviation in the position loop mode of the third spindle
DGN
423
Feedback information of the position coder of the fourth spindle
DGN