15. WAVEFORM DIAGNOSTIC FUNCTION
813
15.4 Output of Storage Type Waveform Diagnosis
Data
Storage type waveform diagnosis data can be output to an input/output unit
connected to the reader/puncher interface.
Set the input/output unit to be used for output in PRM20, 100–135.
In addition, set a code in PRM0#1 (ISO)
(a) Output of data
Storage type waveform diagnosis data can be output to an input /output
unit, according to the procedure below.
1 Set the EDIT mode.
2Press the
SYSTEM
function key, then select the waveform diagnosis
(memory data) screen.
3 Press the soft keys [W.MEM],
, [PUNCH] and [EXEC], in this
order.
For an explanation of input/output to and from the FANUC Floppy Cassette
or FA Card, see item (b).
[SELECT] [ ] [ ] [ ] [ START ]
EDIT **** *** *** 12:15:52
Press
[ ] [ ] [ PUNCH ] [ ] [ ]
[ ] [ ] [ ] [ CAN ] [ EXEC ]
WAVE DIAGNOSE (MEMORY) O1234 N12345
CONDITION: 100 TRIGGER: G0123.4
DATA KINDS SAMPLING AXIS
POS ERROR XYZABCUV
MOTION CMD XYZABCUV
CURRENT (%) XYZABCUV
SPEED (RPM) NONE
TORQUE CMD NONE
HEAT SIMLT XYZABCUV
SMPL TIME : 2.0SEC
DATE : 02/01/13 12:15:00
(b) Output to FANUC Floppy Cassette or FA Card
In the item below, a FANUC Floppy Cassette is referred to as a
Cassette, and a FANUC FA Card as a Card.
(i) Directory
When the directory of a Cassette or Card is displayed, the name of a file
containing storage type wave form diagnosis data is registered as
WAVE DIAGNOS.
The procedure for displaying the directories is described later.
(ii) Output to the Cassette/Card
Servo alarm type waveform diagnosis data can be output to a Cassette
or Card by following the procedure below.
1 Set the EDIT mode.