14
14.4 Operation History
802
14.4.3 Inputting and outputting the operation history data
Recorded data can be output to an input/output unit connected via a
reader/puncher interface. An output record can be input from the
input/output unit.
Set the input/output unit to be used in PRM20, 100–135.
To output the data, set a code in PRM20#1 (ISO).
D Output
(1) Select EDIT mode.
(2) Press the
SYSTEM
key, then select the operation history display screen.
(3) Press the soft keys [(OPRT)],
, [PUNCH], and [EXEC] in this order.
The data output to the FANUC Floppy Cassette or FANUC FA Card is stored
under file name OPERATION HISTORY.
D Input
(1) Select EDIT mode.
(2) Press the
SYSTEM
key, then select the operation history display screen.
(3) Press the soft keys [(OPRT)],
, [READ], and [EXEC] in this order.
14.4.4 Notes related to the operation history
(1) While the operation history screen is displayed, no information can be
recorded to the history.
(2) An input signal having an on/off width of up to 16 msec is not recorded
in the history. Some signals are not recorded in the history.
(3) Once the storage becomes full, old data is deleted, starting from the
oldest record.
(4) The recorded data is retained even after the power is turned off.
(5) The operation history function cannot execute sampling when the
PRM3106#7 (OHS) is set to 1.
14.4.5 Parameter setting
#7
#6 #5 #4 #3 #2 #1 #0
3106
OHS OPH
OPH The operation history screen is:
0 : Not displayed.
1 : Displayed.
OHS The operation history is:
0 : Sampled (recorded).
1 : Not sampled (recorded).
3122
Interval at which the clock time is recorded in the operation history
[Valid data range] 0 to 1439
[Unit of data] Minute
The clock time is recorded to the operation history
at specified intervals. If zero is set as the interval,
ten minutes is assumed. The time is recorded only
when data is recorded within the corresponding
interval.