7. PARAMETERS
437
08508 Switch setting
#0 HM1 : The output type of the first high–speed position
switch is, normal (0)/decision by direction (1)
#1 HM2 : The output type of the second high–speed
position switch is, normal (0)/decision by
direction (1)
#2 HM3 : The output type of the third high–speed
position switch is, normal (0)/decision by
direction (1)
#3 HM4 : The output type of the fourth high–speed
position switch is, normal (0)/decision by
direction (1)
#4 HM5 : The output type of the fifth high–speed position
switch is, normal (0)/decision by direction (1)
#5 HM6 : The output type of the sixth high–speed
position switch is, normal (0)/decision by
direction (1)
#6 HM7 : The output type of the seventh high–speed
position switch is, normal (0)/decision by
direction (1)
#7 HM8 : The output type of the eighth high–speed
position switch is, normal (0)/decision by
direction (1)
08509 Switch setting
#0 HM9 : The output type of the ninth high–speed
position switch is, normal (0)/decision by
direction (1)
#1 HMA : The output type of the tenth high–speed
position switch is, normal (0)/decision by
direction (1)
#2 HMB : The output type of the eleventh high–speed
position switch is, normal (0)/decision by
direction (1)
#3 HMC : The output type of the twelfth high–speed
position switch is, normal (0)/decision by
direction (1)
#4 HMD : The output type of the thirteenth high–speed
position switch is, normal (0)/decision by
direction (1)
#5 HME : The output type of the fourteenth high–speed
position switch is, normal (0)/decision by
direction (1)
#6 HMF : The output type of the fifteenth high–speed
position switch is, normal (0)/decision by
direction (1)
#7 HMG: The output type of the sixteenth high–speed
position switch is, normal (0)/decision by
direction (1)