16
16.2 FSSB Setting Screen
828
The amplifier setting screen consists of the following items:
D NO. (slave number)
The numbers of up to ten slaves (up to eight amplifiers and up to two
separate detector interface units) connected via the FSSB are
displayed sequentially, with the one nearest to the CNC being number
1.
D AMP (amplifier type)
The amplifier type display consists of the letter A, which stands for
“amplifier,” a number that indicates the placing of the amplifier, as
counted from that nearest to the CNC, and a letter such as L (first axis)
or M (second axis) indicating the placing of the axis in the amplifier.
D AXIS NO. (controlled axis number)
The axis number of each controlled axis specified in PRM1920 – 1929
is displayed. If a number specified in these parameters falls outside the
range of between 1 and the maximum number of controlled axes, 0 is
displayed.
D NAME (controlled axis name)
The axis name assigned to a PRM1020 corresponding to a particular
controlled axis number is displayed. If the controlled axis number is 0,
– is displayed.
D The following items are displayed as amplifier information:
⋅ UNIT (servo amplifier unit type)
⋅ SERIES (servo amplifier name)
⋅ CURRENT (maximum rating)
D The following items are displayed as separate detector interface unit
information:
⋅ SEPARATE
This display consists of the letter M, which stands for “separate
detector interface unit” and a number indicating the placing of the
separate detector interface unit, as counted from that nearest to the
CNC.
⋅ TYPE
This display is a letter indicating the type of the separate detector
interface unit.
⋅ PCB ID
This display consists of four digits indicating the separate detector
interface unit ID (hexadecimal). The separate detector interface unit
ID is followed by DETECTOR (8–AXES) for the eight–axis separate
detector interface unit or DETECTOR (4–AXES) for the four–axis
separate detector interface unit.