1.7 Screen Operation Associated with <SYSTEM>
42
1.7 Screen Operation Associated with
SYSTEM
1.7.1 Displaying and setting the parameters
For details of the parameters, see Chapter 7.
(1) Press soft key [PARAM].
0000 SEQ INI ISO TVC
0000000
0001 FCV
00000000
0012 MIR
X00000000
Y00000000
Z00000000
0020 I/O CHANNEL 0
0022 0
[][][][][]
DGNOS PMC SYSTEM (OPRT)
PARAMETER (SETTING) O0010 N00002
>_
MDI **** *** *** 15:43:11
PARAM
(2) Entering values from the MDI panel
1 Enter the MDI mode or emergency stop state.
2 Set PARAMETER WRITE to 1 in the setting screen.
3 Alarm 100 occurs. Press the
CAN
and
RESET
keys simultaneously
to temporarily stop the alarm.
4 Press soft key [(OPRT)] to display the operation menu including
the following:
a) Enter a parameter number and press [NO.SRH]:
Searches for the specified number.
b) Soft key [ON:1]: Sets the value at which the cursor is
positioned to 1. (Only for bit parameters)
c) Soft key [OFF:0]: Sets the value at which the cursor is
positioned to 0. (Only for bit parameters)
d) Soft key [+INPUT]: Adds the entered value to the value at
which the cursor is positioned.
e) Soft key [INPUT]: Sets the value at which the cursor is
positioned to theentered value.
f) Soft key [READ]: Inputs parameters from the reader/
puncher interface or memory card.
For a read operation, set the EDIT mode or
the emergency stop state.
g) Soft key [PUNCH]: Outputs parameters to the reader/
puncher interface or memory card.
For a punch operation, set the EDIT
mode.
An input operation can be performed with the MDI key
INPUT
as well.
5 Upon completion of parameter setting, reset PARAMETER
WRITE to 0 on the setting screen.