11.4 Embedded Ethernet
710
(5) Ethernet–related NC parameters
Among the Ethernet parameters, the parameters for detailed setting
are set
using NC parameters.
Among the Ethernet parameters, the parameters for normal setting
are set
using the dedicated setting screens of (1) through (4).
(a) FACTOLINK
0802
Communication channel
[Data type] Byte
[Valid data range] 21: Select the embedded Ethernet.
#7
#6 #5 #4 #3 #2 #1 #0
0810
MONO TIME BGS
[Data type] Bit
BGD When the FACTOLINK screen is not displayed:
0 : Logging is performed in the background.
1 : Logging is not performed.
TIME Selects the time display format:
0: “01/11/12 00:00” format is used.
1: “Wed Nov 12 00:00:00” format is used.
MONO When the FACTOLINK screen is displayed:
0: Two–tone monochrome display is used.
1 : Color display is used.
0811
Type of logging
[Data type] Byte
[Valid data range] 0, 1, 10, 20, 21
0 : D address area
1 : R address area
10: Fixed data only
20: D address area + fixed data
21: R address area + fixed data
0812
PMC address for logging data
[Data type] Word
[Valid data range] 0 to 65535
Set a start PMC address for storing logging data.
0813
Data length of logging data
[Data type] Word
[Unit of data] Number of bytes
[Valid data range] 0 to 65535
Set the data length of logging data.
0814
Trigger PMC address for logging
[Data type] Word
[Valid data range] 0 to 65535
Set a PMC address that serves as a trigger for
specifying logging data.