B–63172EN/01
22. DISPLAYING AND SETTING DATA
NC FUNCTION
135
The following data are displayed. CRT/MDI or LCD/MDI can display
maximum 640 characters (40 × 16 lines).
The status of the control unit is indicated on the screen. Statuses include
the state when an alarm is being activated or when the system is in the edit
mode. The status line is displayed right above the soft key line.
EDIT STOP MTN FIN ALM hh:mm:ss PATH1
––EMG––
OUTPUT
Status
line
Soft key
line
Operation mode (MDI, AUTO, RMT, EDIT, JOG, TJOG, THND,
STEP, or ZRN)
Status of automatic operation (STOP, HOLD, STRT, or ****)
***** : Reset
STOP : Automatic operation is in a stopped state.
HOLD : Automatic operation is in a halt state.
STRT : Automatic operation has been started.
Axis movement/dwell (MTN, DWL, or ***)
FIN wait state (FIN or ***)
Emergency stop (--
EMG --) (displayed above in 3 and 4)
Alarm status (
ALM , BAT , or ***)
Clock (hh:mm:ss)
Name of the device or path currently selected
NOTE
The name of a device or path can be specified by the
corresponding parameter with a string of up to seven
characters. The characters may be numbers, letters,
katakana characters, or symbols.
Status display such as program editing (INPUT, OUTPUT, SRCH,
EDIT, or LSK)
( and are displayed in the same column. When a program is being
edited, is displayed.)
Data input via the address keys or the numerical keys are displayed at the
left lower part of the screen.
Program number, sequence number is displayed on the right upper part
of the screen.
Alarm number and its contents are displayed briefly.
22.1
DISPLAY
Explanations
D Indication of statuses
D Key input display
D Program number,
sequence number
display
D Alarm display