22. DISPLAYING AND SETTING DATA
B–63172EN/01
NC FUNCTION
142
On the servo setting screen, parameters required for standard initialization
of the servo motor are listed. The parameters can also be set.
SERVO SETTING O0000 N00000
X AXIS Y AXIS
INITIAL SET BIT 00000011 00000001
MOTOR ID NO. 12 12
AMR 00011111 00011111
CMR 2 2
FEEDGEAR N 3 3
(N/M) M 10 10
DIRECTION SET 111 111
VEROCITY PULSE NO. 8000 8000
POSITION PULSE NO. 8000 8000
REF COUNTER 8000 8000
MDI **** *** *** *** 09:36:48
[ SV.SET ][ SV.TUN ][ ][ ][ (OPRT) ]
On the servo adjustment screen, parameters required for basic adjustment
of the servo motor and statuses being monitored are listed for each axis.
SERVO SETTING O1000 N00000
X AXIS
(PARAMETR) (MONITOR)
FUNC.BIT 00110100 ALARM 1 00110100
LOOP GAIN 3000 ALRAM 2 00110100
TUNING ST. 1 ALARM 3 00000000
SET PERIOD 50 ALARM 4 00000000
INT.GAIN 251 LOOP GAIN 3000
PROP.GAIN –2460 POS ERROR 100
FILTER 2450 CURRENT % 50
>_
AUTO STAT MTN *** *** 09:36:48
[ SV.SET ][ SV.TUN ][ ][ ][ (OPRT) ]
22.7
SCREENS FOR
SERVO DATA AND
SPINDLE DATA
22.7.1
Servo Setting Screen
22.7.2
Servo Adjustment
Screen