B-63173EN/02-12
2/4EDIT
DATE DESIG. DESCRIPTION
FANUC Power Mate – i MODEL D/ H
CONNECTION MANUAL
THE FUNCTION OF INCREMENT SYSTEM IS-C
TITLE
DRAW.NO. CUST.
SHEET
01
000530 New design
Data unit
IS-A,IS-B IS-C
Unit
Metric machine 1 mm/minLinear
axis
Inch machine 0.1 inch/min
Rotation axis 1 deg/min
Specify data within the range given in the following table.
Data range
IS-A,IS-B IS-C
Unit
Metric machine 30~
~~
~15000 30~
~~
~12000 mm/minLinear
axis
Inch machine 30~
~~
~6000 30~
~~
~4800 inch/min
Rotation axis 30~
~~
~15000 30~
~~
~12000 deg/min
Replace the description of " NOTE" in the chapter " 2.2.2 INCREMENT SYSTEM" as follows.
NOTE
The IS-A cannot be used in the Power Mate i - D
Delete the description of
"(
((
(Power Mate i – D only)" in the title of "Table 1.2.2(C)" in the
chapter " 2.2.2 INCREMENT SYSTEM"
Replace the description of " NOTE" of the " Parameter of ISA, ISC"
in the chapter " 1.2.2
INCREMENT SYSTEM" as follows.
NOTE
The IS-A cannot be used in the Power Mate i - D
Replace the description of the first table of " 3 axis control feedrate signals EIF0g to EIF15g"
in
the chapter " 15 PMC CONTROL FUNCTION" as follows.
[ Unit of data ]
[Valid of data ]