TITLE
B-63173EN-1/02
EDIT
DATE DESIG. DESCRIPTION
ower
ate i-
The function of expansion of time constant
Connection manual (function)
DRAW.NO. CUST.
SHEET
01
990624 New design
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1605
16051605
1605
TCE
[Data type] Bit
TCE The function of the expansion of time constant is
0:not available(maximum Time constant is 8000)
1:available(maximum time constant depends on number of controlled axes)
In case that this function is available, the range of the time constant shown below is
expanded according to the number of controlled axes as follows.
• Exponential, bell-shaped and linear acceleration/deceleration after interpolation
in cutting feed(Normal mode: Parameter No. 1622, High response mode:
Parameter 0No.1635, No.1638).
• Exponential, bell-shaped and linear acceleration/deceleration after interpolation
in jog feed(Parameter No.1624).
(a) Normal mode(AUTO mode, MDI mode, EDIT mode, etc.)
Number of
control axes
Range of setting value
1∼20∼32000
3∼40∼16000
5∼80∼8000
(b) High speed response mode
Number of
control axes
Range of setting value
1∼20∼4000
3∼40∼2000
5∼80∼1000
Note
After setting this parameter, turn the power off then on again so that the setting will
take effect.