B-63180EN/01-4
EDIT
DATE DESIG. DESCRIPTION
FANUC Power Mate i-D/H
The function of the expansion of time constant
Parameter manual
TITLE
DRAW.NO. CUST.
SHEET
01
990624 New design
Change description of [Valid data range] of parameter No.1622 in “4.8 PARAMETERS OF
ACCELERATION/DECELERATION CONTROL” as follows. Don’t change the description, “Set the time
constant ……” and the figure after [Valid data range].
[Valid data range] ・In case that the function of expansion of time constant is not available.
0∼8000
・In case that the function of expansion of time constant is available.
Number of
control axis
Valid data range
1∼20∼32000
3∼40∼16000
5∼80∼8000
Change description of [Valid data range] of parameter No.1624 in “4.8 PARAMETERS OF
ACCELERATION/DECELERATION CONTROL” as follows. Don’t change the description, “Set the time
constant ……” and the figure after [Valid data range].
[Valid data range] ・In case that the function of expansion of time constant is not available.
0~8000
・ In case that the function of expansion of time constant is available.
Number of
control axis
Valid data range
1∼20∼32000
3∼40∼16000
5∼80∼8000