4.16i/18i DATA SERVER FUNCTIONS IV. OPERATION B-63354EN/04
- -174
4.8.1 Inputting the Parameter
Input files (NC parameters) from the data server built-in hard disk or
host computer built-in hard disk to part program storage.
For the Parameter screen
Procedure
1 Place the CNC in EDIT mode.
2 Press function key
SYSTEM
.
3 Press the continuation menu key at the right end of the soft key
menu.
4 When you press soft key [PARAM], the Parameter screen is
displayed.
5 Press soft key [(OPRT)].
6 Press the continuation menu key at the right end of the soft key
menu.
7 Press soft key [READ].
8 Press soft key [EXEC].
9 During input, "INPUT" blinks in the lower-right part of the
screen.
File name
Fixed to PRAMETER.
File formats and restrictions
Refer to the corresponding CNC operator's manual.
Input source
In storage mode : Data server board built-in hard disk
In FTP mode : Host computer built-in hard disk
In buffer mode : Host computer built-in hard disk
NOTE
In the buffer mode, a specified file behaves as a file
list of files resulting from NC program division.