Power Mate
i
-MODEL D/H
Setting/punch operation for Ethernet Data
with DPL/MDI and DPL/MDI operation
package Specification
B-63354EN/04-01
EDIT DATE DESI
DESCRIPTION
7 /12
CUST.
SHEET
TITLE
DRAW.NO.
3. Parameters for Ethernet function
NOTE
The following parameters can be sent to the Ethernet board only when you use
DPL/MDI or DPL/MDI operation package. When you use LCD/MDI, these
parameters are not sent to the Ethernet board.
In case of LCD/MDI, set the Ethernet data on “Ethernet parameter” screen of
LCD/MDI.
When you read a parameter file, which was punched out, you must set 1 to the 0
bit of No.727 in order to send parameters to the Ethernet board in general
parameter screen.
Data no Data
0704 1st data of IP address for NC
0705 2nd data of IP address for NC
0706 3rd data of IP address for NC
0707 4th data of IP address for NC
(Data type): BYTE
(Valid data range): 0-255
Specifies the IP address of the CNC unit.
Please set as following example.
Example)
In case of IP address for NC is 192.168.0.1, please set 192 to
No.704,
168 to No.705 , 0 to No.706, and 1 to No.707.