Address
0020 I/O DEVICE SELECTION : I / O C H A N N E L
Setting Entry
[Data type] : Byte
[Data range] : 0 to 3
Select an I/ O device used.
0 : Select a device connected to channel 1.
(I/O device connected to JD5A on MAIN CPU BOARD)
1 : Select a device connected to channel 1.
(I/O device connected to JD5A on MAIN CPU BOARD)
2 : Select a device connected to channel 2. (Except Series 21–TA)
(I/O device connected to JD5B on MAIN CPU BOARD)
I/O device usable with P- CODE LOADER is either channel 1 or 2.
NOTE
The Series 21-TA use channel 1.
Bit No.
#7 #6 #5 #4 #3 #2 #1 #0Address
0101 ASI SB2
[Data type] : Bit
SB2 : Number of stop bits:
0 : 1 bit
1 : 2 bits
ASI : Input data code:
0 : ISO
1 : ASCII
NOTE
EIA code cannot be used for P-CODE LOADER.
Address
0102 Specification no. of I/O device (when I/O channel=0)
[Data type] : Byte
Set a specification number of I/O device when I/O Channel=0 according
to Table 1.
Table 1
Set value
Specification of I/O device
0 RS–232–C
1 FANUC CASSETTE ADAPTOR 1 (FANUC CASSETTE B1/B2)
2 FANUC CASSETTE ADAPTOR 3 (FANUC CASSETTE F1)
3 FANUC PROGRAM FILE Mate
FANUC FA CARD ADAPTOR
FANUC FLOOPY CASSETTE ADAPTOR
FANUC SYSTEM P-MODEL H
4 Unused
5 Portable tape reader
6 FANUC PPR
FANUC SYSTEM P–MODEL G
FANUC SYSTEM P–MODEL H
Set 0 for P-CODE LOADER.
I.3
PARAMETER