3. SYSTEM INSTALLATION (SETUP)
B–66102E/10
12
A macro program or a ROM-format file is transferred via the
RS-232-C/GPIB interface. The interface control systems vary between
personal computer manufacturers. Control software including MPOUT,
MROMWT, and MROMWTG is therefore designed to determine the
control system according to the setting of the MDEV environment
variable.
Specify the MDEV environment variable as follows in
AUTOEXEC.BAT before using control software.
Setting of the MDEV environment variable
set MDEV=PC98 : For the NEC PC98 Series
set MDEV=FMR : For the Fujitsu FMR Series
set MDEV=IBM : For the IBM PC Series
When no MDEV environment variable is specified, control software runs
in the control system for the NEC PC98 Series.
The macro compiler or macro linker generates or deletes some temporary
files (work files) for compiling or linking. The destination to which the
temporary files are output can be specified with the MTMP environment
variable.
Setting of the MTMP environment variable
set MTMP=B:\TEMP
If the temporary file output destination is specified as a RAM disk,
compiling or linking time can be reduced.
When no MTMP environment variable is specified, temporary files are
generated in the current directory for compiling or linking and deleted
after compiling or linking
3.5
SPECIFYING
ENVIRONMENT
VARIABLES
3.5.1
Selecting a
RS–232–C/GPIB
Interface Control
System (MDEV)
3.5.2
Specifying a
Temporary File Output
Destination (MTMP)