K. BOOT SYSTEM (FOR Series 15-B/15i-A)
B–66102E/10
APPENDIX
186
(8) Select ”2. SYSTEM DATA CHECK” to retrieve the contents of
F-ROM. After confirming that the P-CODE file has been registered
in F-ROM. Press the input key to return the main menu [Fig. K.3 (b)].
(9) Turn off the power of the CNC unit, and remove the ROM cassette
adapter from the mini slot. After removing the adapter, place the
cover over the slot to protect it.
CAUTION
Avoid using the CNC unit while the ROM cassette remains
in its mini slot. If the CNC unit is used without removing the
ROM cassette, the data stored in the ROM cassette takes
precedence, disabling the use of the micro compiler and
P-CODE file program resident in F-ROM.
(10)Make sure that the registered P-CODE file operates normally.